GKV-15,GKV-15F 3 * 220VAC Three-Phase Under&Over Voltage Phase Sequence Relay(GKV-15)

★★★★★ 4.7 110 reviews

US$21.36
Price when purchased online
Free shipping Free 30-day returns

Sold and shipped by babarkat.af
We aim to show you accurate product information. Manufacturers, suppliers and others provide what you see here.
US$21.36
Price when purchased online
Free shipping Free 30-day returns

How do you want your item?
You get 30 days free! Choose a plan at checkout.
Shipping
Arrives Sep 4
Free
Pickup
Check nearby
Delivery
Not available

Sold and shipped by babarkat.af
Free 30-day returns Details

Product details

Management number 247507797 Release Date 2026/08/16 List Price US$21.36 Model Number 247507797
Category

Phase Monitoring RelaysGeneralVoltage control relays are designed to protect devices with sensitive operating voltage values from faults that may be caused by mains voltage.Usage and Working PrincipleMake the connections of the device in accordance with connection scheme. Set the required settings of the device according to the operating voltage values of the load. When the device is energized, if the voltage valuesare normal according to the set values, the relay gets activated and the relay LED is turned on. (In the case of models with phase sequence control, the phase sequence must also be correct.) When the voltage values go out of the set values,the related fault LED is on, it waits until the delay time (DT), after the time has elapsed, the relay gets de-activatedand the relay LED goes out. When the voltages to their normal values, the device waits until the reset time (RT), after the time has elapsed the relay gets activated and the relay LED is turned on.The High Voltage Protection function is deactivated when the HV control knob is set to off.The Low Voltage Protection function is deactivated when the LV control knob is set to off.Relay is Activated: 2 (COM) and 3 (NC) short circuit,1 (NC) and 2 (COM) open circuit.Relay is De-activated: 2 (COM) and 1 (NC) short circuit, 3 (NC) and 2 (COM) open circuit.Required Settings and Error NotificationsHV: High Voltage Set Value, when the voltage rises above this value, HV LED is on.LV: Low Voltage Set Value, when the voltage drops below this value, LV LED is on.DT: Delay Time, is the time to wait before entering the fault.RT: Reset Time, is the time to wait for the relay to pull when the voltages to normal.LED Notifications By ErrorsProtection FunctionsHigh Voltage Protection- To enter the error state: If one or more of the phases goes above the high voltage set value, the HV LED is on, the device waits untilthe set delay time (DT), after the time has elapsed the relay gets de-activated and the relay LED is off.High Voltage Protection-Exiting the error state: When all phases drops below by 3% of the high voltage set value, the device waits for the reset time (RT) After the time passes, the HV LED is off, the relay gets activated and the relay LED is on.High Voltage Fuse Protection To enter the error state: If one or more of the phases exceeds 1.5 times the rated operating voltage, the HV LED is flashes, after 100 milliseconds the device gets de-activated the relay, and the relay LED is turned off.High Voltage Fuse Protection - Exiting the error state: When all phases drops below by 3% of the high voltage set value, the device waits for the reset time (RT). After the time passes, the HV LED is off, the relay gets activated and the relay LED is on.Low Voltage Protection - To enter the error state: If one or more of the phases goes below the low voltaget set value, the LV LED is on, the device waits until the set delay time (DT), after the time has elapsed the relay gets de-activated and the relay LED is off.Low Voltage Protection - Exiting the error state: When all phases goes above by 3% of the low voltage set value, the device waits for the reset time (RT). After the time passes the LV LED is off, the relay gets activated and the relay LED is on.Low Voltage Fuse Protection- To enter the error state: If one or more of the phases 0.5 times below the rated operatinq voitage, the LV LED is flashes, ater 100 milliseconds the device gets deactivated the relay, and the relay LED is turned off.Low Voltage Fuse Protection - Exiting the error state: When all phases goes above by 3% of the high voltage set value, the device waits for the reset time (RT) After the time passes, the LV LED is off, the relay gets activated and the relay LED is on.Inadequate Supply Voltage Protection - To enter the error state: LV and HV LEDs flashes when N-L1 voltage for is lower than the nominal operating voltage by 0.4 times. After 100 millisecond the device gets de-activated the relay, and relay LED is turned off.Inadequate Supply Voltage Protection- Exiting the error state: When N-L1 voltage values goes above by 3% of the low voltage set value, the device waits until the reset time (RT), after the time has elapsed, the LV and HV LED sturn off.The relay gets activated and relay LED is on.Phase Sequence Protection: If the phase sequence of the device is reversed, the phase sequence error LED (X) light up and the relay will not gets activated (only in GKV -13F).Phase Absence Protection: If one of the phases is not connected to the device, the phase absence error LED (L) flashes (only in GKV-13).MaintenanceSwitch off the device and release from connections. Clean the trunk of device with a swab. Don't use any conductor or chemicalmight damage the device. Make sure device works after cleaningWarnings-Please use the device according to the manual.-Don't use the device in wet.-Include a switch and circuit breaker in the assembly.-Put the switch and circuit breaker nearby the device, operator can easily.-Mark the switch and circuit breaker as releasing connection for device.SpecificationsOperating Volt....: 3 x 220V AC 50/60Hz.High Voltage.......:230V-300VLow Voltage........:140V-210VDelay Time..........:0.1 sec. - 20 sec.Reset Time..........:0.1 sec. -20 sec.<;6VAOperating Temperature..: -20°C.....+55°CDisplay................: 4xLEDsConnection Type..............: Terminal ConnectionContact....................:5A/250V AC (Resistive Load)Cable Diameter.................: 1,5mm²Weight...............................: 0.210Kg.Mounting....................: Assembled on the din rail<;2000meterDimensionsConnection diagram

  • Phase Monitoring Relays
  • GKV-15,GKV-15F 3*220VAC Three-Phase Under&Over Voltage Phase Sequence Relay
ASIN B0HDBK7DJ3
Model TGVNUFDEK
Brand Name TGVNUFDEK
Part Number TGVNUFDEK
Manufacturer TGVNUFDEK

Correction of product information

If you notice any omissions or errors in the product information on this page, please use the correction request form below.

Correction Request Form

Customer ratings & reviews

4.7 out of 5
★★★★★
110 ratings | 45 reviews
How item rating is calculated
View all reviews
5 stars
86% (95)
4 stars
2% (2)
3 stars
1% (1)
2 stars
1% (1)
1 star
10% (11)
Sort by

There are currently no written reviews for this product.